  1. ANAF or ONAN transformers | Eng-Tips

    Jun 5, 2007 · Two questions:- 1. I have only ever come across ANAF transformers fitted indoors. Are they ever used outdoors, particularly if it is a high ambient temperature environment? 2. What is the …

  2. Transformer AN vs AF | Eng-Tips

    Apr 18, 2007 · Hi Buddy, need your guidance on this:- For each transformer, there is 2 rating involved , AN and AF. Lets say AN/AF = 2.0/2.5MVA. Shall there be any difference with the transformer with …

  3. OA\FA ONAN\ONAF diferent? | Eng-Tips

    Apr 12, 2002 · Please tel me what is the difference between OA\\FA and ONAN\\ONAF? What mean when it is said that power ratings are given at OA ta 55oC and FA at 56oC temperature rise? Where I …

  4. DCP to SPT N-value correlations | Eng-Tips

    May 9, 2008 · Aside from a few graphs laying around the office here that appear to have been photocopied for the last 10 years... what is a reliable source for a DCP to SPT correlation? idealy i'm …

  5. ETAP generator modeling - swing & voltage control | Eng-Tips

    Mar 26, 2009 · You cannot have both swing and voltage control properties at the same time. I typically put all the generators in the swing mode. As far as I think, the current ramp starter will not help in the …

  6. Column Numbering System | Eng-Tips

    Nov 4, 2003 · Can anyone direct me to a published standard for column numbering within a factory? Any help would be much appreciated. Thanks

  7. Maximum Allowable Pressure Drop | Eng-Tips

    Jan 27, 2009 · I'm designing a new piping system for a client, They have an inhouse specification that indicates that the maximum allowable pressure drop in a pipe carying dry fuel gas is 11.5kPa/100m. …

  8. Rivet Callout | Eng-Tips

    Jul 10, 2006 · Hello all, I'm new here and have a question: I need to decipher a river callout on a drawing, and I'm unsure of what this symbol is. I have a series of rivets, and pointing to one of the …

  9. Alarm / Trip Settings for Class F/B Motor | Eng-Tips

    Mar 15, 2022 · Motor Insulation class is F with B temperature rise. The Motor vendor recommends to set the alarm / trip value at 140 degree Celsius and 155 degree Celsius respectively. Max Ambient …

  10. Save Failed Modeler error: irrecoverable run-time error | Eng-Tips

    Nov 14, 2014 · Eng-Tips is the largest forum for Engineering Professionals on the Internet. Members share and learn making Eng-Tips Forums the best source of engineering information on the Internet!